Used Cisco by Alliance Datacom
  

Telecom: 12:1 Multi-line System Mulitplexer

12 Lines over existing twisted pair: Expand customer service to a range of up to 100 Kft without the expense of installing copper

The 12:1 Multi-Line System multiplexes 12 64 Kbps Clear channel POTS lines and transports them over a single twisted pair utilizing noiseless, low power 2B1Q line coding. These POTS lines can be demultiplexed along the drop using Add/Drop Units (A/D) or at the end using either a Remote Terminal (RT) RT12 or a 2 line Add/Drop End Unit (A/DE)

The 12:1 Multi-Line System transports CLASS® services to distances of up to 100 Kft from the Central Office (CO) or Digital Loop Carrier (DLC) to the customer premises.

  • OSMINE compliant
  • Compatible with V.34 modem speeds
  • Flexible configuration
  • Replaces analog carrier systems 82A and CM8
  • NEBS Level 3 certified (CO equipment)
  • UL approved
  • CSA certified
System Components

Central Office Terminal (COT) Line Card

  • Provides 12:1 Digital Pair-Gain (DPG)
  • 2B1Q line coding
  • Mounts in 200 series shelves
  • LED indicators for power, alarms and add/drop synchronization
  • Uses twisted pair infrastructure
  • 4TEL, MLT or GR-909 line testing signatures
  • NEBS level 3 compliant

 

Power Supply

  • Input to power supply is a -48V DC battery
  • Powers up to five COT line cards
  • 2 powers supplies required per shelf for 10 DSLs
  • DSL voltages available: ±190V, ±130V or ±100V DC

 

2 Line Add/Drop (A/D) Unit
2 Line Add/Drop (A/DE) End Unit

  • Power and sync LED indicators
  • Line powered
  • Can be used in Distributed or Hybrid configurations
  • Supports up to 200 ohm drop lengths
  • Extends DSL distance up to 24,800 ft. on 19 AWG
  • Rugged design for use at -40° to 65°C (-40° to +149° F)

 

Remote Terminal (RT) - RT12

  • Drops up to 12 POTS lines
  • Supports up to 200 or 400 ohm drop lengths
  • Line and Express Power configurations
  • Can be used in combination with Point-to-Point or Hybrid configurations
  • Sync LED indicator
  • Extends DSL distance up to 24,800 ft. on 19 AWG
  • Rugged design for use at -40° to 65°C (-40° to +149° F)

 

Alarm Card

  • One card per 200 series shelf
  • Visual and audible status alarms
  • Self-test function
 

 

 

Pole /  Wall / Pedestal Mount Repeater & Isolation Repeater

  • Extends DSL distance up to 24,800 ft. on 19 AWG
  • Line powered
  • LED for sync indication
  • Rugged design for use at -40° to 65°C (-40 to +149°F)
  • Weather-tight housing
  • Isolation Repeater required for Back Power configurations
 

Express Power Card

  • Extends DSL distance
  • Application requires one Express Power Card per COT Line Card
  • Rugged design for use at -40° to 65°C (-40° to +149° F)

 

Remote Terminal Cabinet (RTC) - RTC12 & RTC24

  • Line powered
  • Drops up to 24 POTS lines
  • Supports 200 or 400 ohm drop lengths
  • Meets the environmental stressing sections of GR-487-CORE
  • Houses up to two Mid-Span / Remote Terminal Power Supplies (±130V) per cabinet
  • Extends DSL distance up to 24,800 ft. on 19 AWG
  • 3 options for extended reach applications:
    - Express Power
    - Local Power (requires BBU for lifeline service)
    - Back Power (requires BBU for lifeline service)
  • Rugged design for use at -40° to 65°C (-40° to +149° F)
  • Cable stubs available upon request

 

 

 Remote Terminal Power Supply 

  • Local and Back Power configurations require one power supply per DSL
  • Input power from BBU or 115V AC
  • Provides GR-1089 A2 protection
  • Double-wide CS-239 size mechanics

 

 

Battery Backup Unit (BBU)

  • 28 amp-hours @ 3.5 amps continuous backup service
  • Meets the environmental stressing sections of GR-487-CORE
  • LED indicators for proper operation, low battery and fault conditions
  • Major and minor alarm reporting capabilities
  • Analog meters for DC voltage and DC amperage status
  • Rugged design for use at -40° to 65°C (-40° to +149° F)

 

200 Series Shelf and Baffle

  • 23” DML 201 shelf; maximum 120 lines (13 slots, 10 COT line cards); uses 7” of vertical rack space (four rack units)
  • 19” DML 205 shelf; maximum 84 lines (10 slots, 7 COT line cards); uses 7” of vertical rack space (four rack units)
  • Baffles for 19” and 23” shelves; uses 1.75” of vertical rack space (one rack unit)

 

 

200 Series Fan Tray

  • Fan trays for 19” and 23” shelves; uses 1.75” of vertical rack space (one rack unit)
  • Fan trays feature 172 CFM output and quiet operation

 


Configurations